Rockwell Automation Publication PFLEX-AP009A-EN-P - September 2012 117
Drive Comparisons Chapter 1
FlexPak 3000 Pulse Encoder Interface Kit
See the FlexPak 3000 Pulse Encoder Interface Kit Installation Instructions,
publication FP3-IN008
, for details.
Figure 91 - Pulse Encoder Interface Board Terminal Block Location
ATTENTION: Do not route pulse encoder wiring with AC and DC power or logic
control wiring in the same conduit. This may cause interference with drive
operation. Failure to observe this precaution could result in damage to or
destructions of the equipment.
ATTENTION: Do not ground any pulse encoder wiring connection. Failure to
observe this precaution could result in damage to or destructions of the
equipment.
71 72 73 74 75 76
71 72 73 74 75 76
71 72 73 74 75 76
71 72 73 74 75 76
Carrier Pivot Point Cable Routing
Pulse Encoder
Interface Board
Table 16 - Pulse Encoder Interface Board Wiring
Twisted Pair Number Signal Terminal Number
1 +15V DC 71
15V DC Common 72
2A73
A Not 74
3B75
B Not 76