Allen-Bradley 1770-M10 Dokumentacja Strona 146

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 194
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 145
146 Rockwell Automation Publication PFLEX-AP009A-EN-P - September 2012
Chapter 1 Drive Comparisons
Figure 102 - Frame B Field AC Input Line Fuses Location
Frame C and D Fuse Designations
All fuses for armature and field circuit protection are internally mounted and
provided with frame C and D drives.
Top View of Drive
Field circuit fuses
U V W
C D
FS3
FS4
C1 D1
U1 V1
M
FS3 = Internally
mounted fuses for
the field circuit on
the AC input side.
FS4 = Internally
mounted fuses for the
armature converter on
the AC input side.
Przeglądanie stron 145